Description : Power Entry Modules (PEM) RoHS
Mfr. Part # : 2005V3
Model Number : 2005V3
The Anderson Power Saf-D-Grid connector system builds upon the proven contact technology of SB and Powerpole connectors, offering enhanced features for higher voltage DC or hybrid AC/DC systems. Designed to meet international safety requirements, Saf-D-Grid connectors enable greater power density by allowing up to 40A and 600V DC or AC within the same footprint as IEC 620 C13/C14 connectors, which are limited to 10A and 250 VAC. These connectors are suitable for hazardous, low voltage applications and are rated for current interruption for both electronic and electrical loads. Saf-D-Grid provides safety through a first-mate, last-break ground contact and an integral latch to prevent accidental unmating. They are ideal for renewable and alternative energy sources, ensuring system uptime.
| Specification | Saf-D-Grid 400V | Saf-D-Grid 300V (AC Applications) |
|---|---|---|
| Voltage Rating (AC/DC): | 600V (UL/CSA), 400V (IEC) | 600V (UL/CSA), 400V (IEC) |
| Current Rating (UL 1977): | See Table on Page 5 | See Table on Page 5 |
| Current Interrupt (AC/DC): | 600V (UL/CSA), 400V (IEC) | 600V (UL/CSA), 400V (IEC) |
| Wire Range: | 10 AWG to 18 AWG (0.75 mm to 5.5 mm) | 10 AWG to 18 AWG (0.75 mm to 5.5 mm) |
| Operating Temperature: | -4 to 176F (-20 to 105C) | -4 to 284F (-20 to 105C) |
| Contact Retention: | 20 lb (89N) | 20 lb (89N) |
| Plug Latch Retention: | 20 lb (89N) | 20 lb (89N) |
| Panel Latch Retention: | 60 lb (267N) | 60 lb (267N) |
| Durability: | 5,000 Cycles (no load) | 5,000 Cycles (no load) |
| Receptacle Max Wire Size: | 10 AWG (4.0 mm) | N/A |
| Creep and Clearance: | 7.0 mm min | 7.0 mm min |
| Max PCB Thickness (PCB contacts): | 0.093" (2.4 mm) | N/A |
| Mechanical Shock (IEC 60512-4-6C): | 50g | 50g |
| Vibration (IEC 60512-4-6d): | 20g | 20g |
| Dielectric Withstanding Voltage: | 3300V | 3300V |
| Fault Current Withstand (UL 467): | 14 AWG, 300V, 4s (10 AWG, 750V, 4s) | 14 AWG, 300V, 4s (10 AWG, 750V, 4s) |
Note: Specific part numbers for receptacles, plugs, and cable assemblies are detailed in the provided document, including variations in panel mount thickness, termination style, key configuration, and cable specifications. Refer to the detailed tables for exact ratings and approvals for each model.
|
|